LOW FLOW RANGE - TWO PORT VERSION
VALVE FOR USE IN PURE GAS SUPPLY SYSTEMS, Diaphragm shut-off valve
2-port metal diaphragm shut-off valve is used in supply systems for pure, inert, flammable, oxidizing, corrosive, toxic gases and gas mixtures. Maximum gas purity is 6.0.
SPECIAL FEATURES
- Elgiloy diaphragm tighting system to atmosphere
- Compact design
- Designed and approved in accordance with relevant sections of EN ISO 10297:2015
- O2 ignition test regarding EN ISO 10297 for brass chrome plated version
- Electrostatic chargeability test
- Fulfils requirements according to DIN EN ISO 80079-36; IEC TS 60079-32-1 and German TRGS 727
- Usable in EX-areas zones 1 and 2 for gases with explosion risk group I; IIA; IIB; IIC
TECHNICAL DATA
Working temperature: | -20°C to +60°C |
Max. working pressure: | 300 bar |
Cv-value: | 0,25 |
Seat diameter: | 5 mm |
Material: | Brass chrome plated or Stainless Steel |
Technical datasheets
Direct link to druva product configurator