Group Number: 3611

Whole medical range is available on

Manifold MM40 – STABILIZER is a second stage pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units.
MM40 – STABILIZER is only second stage reduction unit where the primary gas supply is provided by high pressure gas manifolds (such as MM40 – HP Unit). In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send information to the central operation control.
The stabilizer can be delivered with either pressure transmitter 4–20 mA, pressure transmitter 0–50 mV or with pressure switches. Gas reduction unit MM40 – STABILIZER must always be installed in compliance with the standards
EN ISO 7396-1 and the appropriate national standards.

FOR A COMPLETE MM40 STABILIZER MANIFOLD ADD:

  • Plastic cover for locking
  • Alarm unit (included if ordered together with HP unit)
 Item No. Denomination Gas PRV Alarms
0727329 MM40 – Stabilizer O2, N2O, Air, CO2, N2
0727337 MM40 - Stabilizer AIR-800
0727332 MM40 - Stabilizer O2, N2O, Air, CO2, N2 With pull-ring Pressure
switch
0727344 MM40 - Stabilizer O2, N2O, Air, CO2, N2 With pull-ring 4-20 mA
0727343 MM40 - Stabilizer O2
0727346 MM40 - Stabilizer Air
0727347 MM40 - Stabilizer Air-800
0727348 MM40 - Stabilizer CO2
0727364 MM40 - Stabilizer N2O

ACCESSORIES

 Item No. Denomination 
 COM001002  Locable cover

735100000796 MM40 Stabilizer leaflet EN

TECHNICAL DATA

Gases: O2, Air, Air-800, N2, N2O, CO2, (all medical gases)
Nominal flow: 40 m3h
Inlet maximal pressure: 16 bar
Outlet nominal pressure: 4,5 bar (setting range 0,5 – 10 bar)
Inlet connection 1: G1/2"M + soldering piece pipe ∅ 12 mm
Inlet connection 2: Optional (G1/2"M + soldering piece pipe ∅ 12 mm)
Outlet connection: G1/2"M + soldering piece pipe ∅ 12 mm
Pressure relieve valve: Optional (6,8 bar; outlet pipe ∅ 15 mm)
Pressure sensors: Optional (Pressure switches; Transmitters 0–50 mV; 4–20 mA)
Emergency QC inlet: Optional QC by national standards
Regulatory status:

Complies with Medical Devices Directive 93/42/EEC

Complies with EN ISO 7396-1 (Central Gas Supply Systems)

Complies with EN 60601-1-2 (Electromagnetic compatibility)

present SIS HB 370 and HTM 02-01

 